to_pandapower#
- andes.interop.pandapower.to_pandapower(ssa, ctrl=[], verify=True, tol=1e-06)[source]#
Convert an ADNES system to a pandapower network for power flow studies.
- Parameters
- ssaandes.system.System
The ADNES system to be converted
- ctrllist
The controlability of generators. The length should be the same with the number of
StaticGen
. If not given, controllability of generators will be assigned by default. Example input: [1, 0, 1, ...];PV
first, thenSlack
.- verifybool
If True, the converted network will be verified with the source ANDES system using AC power flow.
- tolfloat
The tolerance of error.
- Returns
- pandapower.auxiliary.pandapowerNet
A pandapower net with the same bus, branch, gen, and load data as the ANDES system
Notes
Handling of the following parameters:
Generator cost is not included in the conversion. Use
add_gencost()
to add cost data.By default, all generators in
ssp
are controllable unless user-defined controllability is givenThe online status of generators are determined by the online status of
StaticGen
that connected to theSynGen
orDG
ssp.gen.name
is fromssa.StaticGen.idx
, which should be unique